Name: Nylon Filter Membrane, PA Filter Membrane, Polyamide Filter Membrane
Type: Single-layer cast membrane.
Material: 100% polyamide 66, homogeneous.
Properties: Hydrophilic (naturally)
Pressure: Operating pressure <0.6 MPa (long-term)
Temperature: <130°C (normal), steam sterilizable.
Chemical: Resistant to common chemicals, *Not resistant to strong acids and polar solvents. (such as NMP, DMAC).
Welding: Adhesive bonding, hot press lamination, low-frequency ultrasonic welding.
Working way: deep retention, core interception of the membrane.
* The intercepted media will be retained in the core layer of the membrane and discarded together, which may cause media loss.
* If not, please click (UHMW-POF) to view our surface interception type membrane.
Model (HGL-1-NY) and Base Data:
* PMI pore size analysis: pore size range, average pore size, porosity.
* Pore size retention efficiency: Standard particle count.
* Molecular weight cutoff efficiency: Bovine serum albumin, PEG.
* Surface properties: Contact angle measurement.

Standard Size: (Roll)
Width: 254-508mm (customizable)
Length: 100m (min)